Command Reference
56 Elektronik-Systeme Lauer, MAEN976
6.16 MCC_BLUELEVEL (0xB6)
Blue Channel Level
Adjusts the level of the blue channel.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x07 ADR 0x4D 0x43 0x43 LEN ICHKH 0xB6 Param ICHKD
Param: ABSOLUTE
Value: “00”: low...“FF”: high
Type: Two-digit ASCII-encoded hexadecimal number
Length: 2
Description: New value for the blue channel
Param: INC
Value: “+” (0x2B)
Type: ASCII character
Length: 1
Description: Increment the current value of the blue channel
Param: DEC
Value: “-” (0x2D)
Type: ASCII character
Length: 1
Description: Decrement the current value of the blue channel
Param: RESET
Value: “R” or “r” (0x52 or 0x72)
Type: ASCII character
Length: 1
Description: Reset the value of the blue channel to an internally
predefined value
Param: QUERY
Value: ?” (0x3F)
Type: ASCII character
Length: 1
Description: Query the current value of the blue channel