Command Reference
30 Elektronik-Systeme Lauer, MAEN976
Example 3
Increment the current brightness level of monitor at address 0.7 (group 0, address 7):
Monitor at address 0.7 (group 0, address 7) has returned the new brightness level 201
(0xC9):
Example 4
Reset the brightness level of monitor at address 0.7 (group 0, address 7):
Monitor at address 0.7 (group 0, address 7) has returned the default brightness level
128 (0x80):
0 1 2 3 4 5 6 7...8 9
0x07 0x07 0x4D 0x43 0x43 0x02 0x1C 0x81 0x2B 0x53
0 1 2 3 4 5 6 7...10 11
0x06 0x07 0x4D 0x43 0x43 0x04 0x1B 0x81 0x2B 0x43 0x39 0xD7
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4D 0x43 0x43 0x02 0x1C 0x81 0x52 0x2C
0 1 2 3 4 5 6 7...10 11
0x06 0x07
0x4D 0x43 0x43 0x04 0x1B 0x81 0x82 0x38 0x30 0xC4