Beijer-electronics SCOM Protocol EN Manual de usuario Pagina 118

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 143
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 117
Command Reference
118 Elektronik-Systeme Lauer, MAEN976
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
11
Example
Assign command “Special functions 2” to the digital input port of the monitor at ad-
dress 0.7 (group 0, address 7):
The monitor at address 0.7 (group 0, address 7) acknowledged the new command
for the digital input port:
0 1 2 3 4 5 6 7...9 10
0x06 ADR 0x4C 0x41 0x55 0x03 ICHKH 0x02 0x06 Ret ICHKD
Ret
Value: 0x00: Command “No operation”
0x01: Command “Set brightness”
0x02: Command “Special functions 1”
0x03: Command “Special functions 2”
Type: Byte
Length: 1
Description: Current command assigned to the digital I/O port
0 1 2 3 4 5 6 7...9 10
0x07 0x07 0x4C 0x41 0x55 0x03 0x0C 0x02 0x06 0x02 0xF5
0 1 2 3 4 5 6 7...9 10
0x06 0x07
0x4C 0x41 0x55 0x03 0x0D 0x02 0x06 0x02 0xF5