Command Reference
36 Elektronik-Systeme Lauer, MAEN976
Example 2
Reset the scaling mode of monitor MT226 at address 0.15 (group 0, address 15):
Monitor MT226 at address 0.15 (group 0, address 15) has returned the default scal-
ing mode “Full screen” (which is ASCII “0” with ASCII-code 0x30):
Example 3
Query the current scaling mode of monitor MT226 at address 0.15 (group 0, address
15):
Monitor MT226 at address 0.15 (group 0, address 15) has returned the current scal-
ing mode “Full screen” (which is ASCII “0” with ASCII-code 0x30):
0 1 2 3 4 5 6 7...8 9
0x07 0x0F 0x4D 0x43 0x43 0x02 0x14 0x8C 0x52 0x21
0 1 2 3 4 5 6 7...9 10
0x06 0x0F 0x4D 0x43 0x43 0x03 0x14 0x8C 0x52 0x30 0xF1
0 1 2 3 4 5 6 7...8 9
0x07 0x0F 0x4D 0x43 0x43 0x02 0x14 0x8C 0x3F 0x34
0 1 2 3 4 5 6 7...9 10
0x06 0x0F 0x4D 0x43 0x43 0x03 0x14 0x8C 0x3F 0x30 0x04