Command Reference
20 Beijer Electronics, MAEN993
5.5 TYP
Unit Type and Model Number
Queries the device type and model.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
(This command has no data)
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
(No data is returned, in case of a negative acknowledge)
Maximum Lr for this Command
23
Example
Query the unit type and model of the device at address 0.7 (group 0, address 7):
According to the data returned by the device (“Lauer RBC”) at address 0.7 (group 0,
address 7), this is a device of the Beijer Electronics RBC series:
0 1 2 3 4 5 6
0x07 ADR
0x54 0x59 0x50 0x01 ICHKH
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR 0x54 0x59 0x50 LEN ICHKH Type/Model ICHKD
Type/Model
Value: ASCII characters
Type: String
Length: 1...15
Description: Device type and model
0 1 2 3 4 5 6
0x15 ADR
0x54 0x59 0x50 0x00 ICHKH
0 1 2 3 4 5 6
0x07 0x07 0x54 0x59 0x50 0x00 0xF4
0 1 2 3 4 5 6 7-15
0x06 0x07 0x54 0x59 0x50 0x09 0xEC 0x4C 0x61 0x75 0x65
7-15 16
0x72 0x20 0x52 0x42 0x43 0xB9