Command Reference
18 Beijer Electronics, MAEN993
5.4 POT
Local Control
Enables or disables the local backlight level control. If the local backlight control is
enabled, the backlight level can be changed using the front panel buttons and by re-
mote control (RS232, RS485 or USB interface). If the local backlight control is dis-
abled, the backlight level cannot be changed using the front panel buttons. It can still
be changed by any remote control message.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
0 1 2 3 4 5 6 7 8
0x07 ADR 0x50 0x4F 0x54 0x01 ICHKH Local control ICHKD
Local control
Value: 0x00: Disable local backlight control
0xFF: Enable local backlight control
Type: Byte
Length: 1
Description: New local control configuration
0 1 2 3 4 5 6 7 8
0x06 ADR 0x50 0x4F 0x54 0x01 ICHKH Local control ICHKD
Local control
Value: 0x00: Local backlight control disabled
0xFF: Local backlight control enabled
Type: Byte
Length: 1
Description: Current local control configuration
0 1 2 3 4 5 6 7 8
0x15 ADR 0x50 0x4F 0x54 0x01 ICHKH Local control ICHKD
Local control
Value: 0x00: Local backlight control disabled
0xFF: Local backlight control enabled
Type: Byte
Length: 1
Description: Last local backlight control configuration