Hardware Replacement
7.6 ReplacingtheBacklight
Note:
Alllampsinthedisplaymustbereplacedatthesametime.
The following is needed:
Two new backlights, see Available Spare Parts for iX P anel T A150
AtorxT10screwdriver
A screwdriver Phillips size 0 or 00
Note:
MakesuretouseadequateESDprotection.
Follow the steps below to replace the battery of the iX Panel TA150:
1.
First, follow the steps 1–5 in section Replacing the Rear Cover.
2.
Remove the two cross-headed screws to the backlight, using the Phillips size
00 screwdriver. This way, backlights can be removed without removing the
plate.
2 x cross headed screw
2 x backlight
3.
Remove the backlights.
4.
Insert the new backlights. Be careful not to pull the cables of the new
backlights when inserting them, sinc e pulling the cables will damage the
backlights.
5.
Re-assemble the complete operator panel.