Beijer-electronics SCOM Protocol EN Manual de usuario Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 131
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
Ethernet Communication
10 Beijer Electronics, MAEN975
WINS
WINS (Windows Internet Naming Service) allows a Beijer Electronics MT230 Nau-
tic Monitor to register a unique name (host name) and map it to its IP-address. Once
registered, the Beijer Electronics MT230 Nautic Monitor can be accessed using this
configurable name, without the knowing its IP-address.
Definition of Host Name
By default, the host name of a Beijer Electronics MT230 Nautic Monitor is defined
using the last two bytes of its MAC-address, converting it to its hexadecimal ASCII
representation and finally succeeding the three characters “LAU”.
Example
A Beijer Electronics MT230 Nautic Monitor with the MAC-address 00-30-AC-10-
17-1A has the host name “LAU171A”, if it is not changed by the user.
Sample Application
The sample communication application chapter shows the full source code of a sim-
ple command line application, developed in plain ANSI-C, including necessary pro-
gram snippets to communicate with a Beijer Electronics MT230 Nautic Monitor via
Ethernet. The sample code can be ported to any operating system supporting ANSI-
C with none or little development effort.
Related information
Command Reference
Related information
Sample Communication Application
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 130 131

Comentarios a estos manuales

Sin comentarios