User Guide Revision 1.12
Internal Value, Contact your local Drive Distributor
Load Torque Profile Current Values
Parameter contains the 5 Current values measured during the Load Torque Characteristic Auto-Tune function.
Five entry display: First display – Current at minimum speed
Second display – Current at first measurement interval
Third display – Current at second measurement interval
Fourth display – Current at third measurement interval
Fifth display – Current at maximum speed
Displays the speed reference from the Frequency input channel
Displays the calculated slip speed in Hz or rpm
Relay Control Speed Hysteresis
Relay control speed hysteresis
Post ramp speed reference
Displays the post ramp speed reference in Hz or rpm
Displays the actual effective Switching frequency. This may be less than the value set in P2-24 if reduced by the thermal fold-back
function (enabled in P6-02)
Displays the time for which the drive has been powered up in Hours, Minutes and Seconds since date of manufacture
Displays the User ramp value received from the Fieldbus interface. This ramp function is only active when P5-07 = 1 (Enabled)
Internal Value, Contact your local Drive Distributor
Option Module identification code
Identifies Type of Option Module connected to drive option module slot
Fieldbus module Identification Code
Displays the drive internal ambient temperature
Displays the value of the internal 24hour counter, displayed in Hours and Minutes. This value can be set using the drive keypad (UP
and DOWN keys when drive stopped) and will be reset to zero on power up.
Displays the L1 line input voltage
Displays the L2 line input voltage
Displays the L3 line input voltage
Internal Value, Contact your local Drive Distributor
Internal Value, Contact your local Drive Distributor
Control/boot-loader version
Displays the boot-loader version and motor control library version
Specified internal parameter
Displays the value selected by P6-28. Usually used in conjunction with the PLC function.